Osmolal Gap Calculator

Estimate osmolal gap from measured and calculated serum osmolality.

Understanding this tool

Why nurses use it

Osmolal gap (measured minus calculated osmolality) suggests unmeasured osmoles — toxic alcohols, ethanol, or other substances in ingestion workups.

When to use it

Use when toxic ingestion, unexplained osmolality, or high-gap metabolic acidosis is suspected.

Calculate

Converted to mg/dL for calculation.

How to use this calculator

  1. Enter measured osmolality and lab sodium, glucose, BUN.
  2. Review gap — elevated gap warrants further toxicology workup.

How the calculation works

Calculated osm ≈ 2×Na + glucose/18 + BUN/2.8 (US units). Gap = measured − calculated.

Osm gap = Measured osm − Calculated osm (2×Na + glucose/18 + BUN/2.8)

Formula used by this tool — verify units before applying at the bedside.

Worked example

Measured 310, calculated ~290 → gap ≈ 20 mOsm/kg (investigate unmeasured osmoles).

Limitations & clinical notes

  • Calculated osm formula variants exist; use local lab alignment.
  • Ethanol requires separate calculation if suspected.

References

Key sources: Toxic alcohol ingestion workups.

Don’t miss new nursing tools

Subscribe for alerts when we add calculators, clinical scores, and reference updates to NurseOnShift.

Subscribe

Disclaimer: This calculator is for educational and bedside double-check purposes only. It does not replace institutional protocols, prescriber orders, pharmacist verification, or clinical judgment. Always follow your local policies — especially for high-risk medications, infusions, pediatrics, and critical care. If the patient is acutely unwell, escalate immediately rather than relying on any calculator output.